SMTP (E-mail Transmission)
Item
Factory
default
setting
Description
Web page
Configuration
Tool/Network
Setting plug-in
Network
Card Setup
(Mac OS X)
SMTP Send
-
-
DISABLE
Sets whether to use the SMTP (E-mail).
SMTP Server
-
-
(NULL)
Sets the SMTP server name. Enter a domain name or IP address. If you
are using a domain name, you must set the DNS (Pri)(Sec).
SMTP Port
Number
-
-
25
Sets the SMTP port number. For general use, use the initial value.
Printer Email
Address
-
-
(NULL)
Sets the E-mail address of the printer.
Reply-To
Address
-
-
(NULL)
Sets the reply-to address. For general use, use the network
administrator's E-mail address.
Email Address
1-5
-
-
(NULL)
Sets the destination address. You can register up to five addresses.
Way of Email
Alerting
-
-
Upon
occurrence
of an
event
Sets the method of failure notification.
Email Alert
Interval
-
-
24
Sets the notification cycle. This setting is only valid when periodic
notification is selected.
Consumable
(Warning)
-
-
Immediate Sets whether to issue notifications for warnings related to printer
consumables (toner cartridge, image drum, etc.). This setting is only
valid when notification upon occurrence is selected.
Consumable
(Warning)
-
-
ENABLE
Sets whether to issue notifications for warnings related to printer
consumables (toner cartridge, image drum, etc.). This setting is only
valid when periodic notification is selected.
Consumable
(Error)
-
-
Immediate Sets whether to issue notifications for errors related to printer
consumables (toner cartridge, image drum, etc.). This setting is only
valid when notification upon occurrence is selected.
Consumable
(Error)
-
-
ENABLE
Sets whether to issue notifications for errors related to printer
consumables (toner cartridge, image drum, etc.). This setting is only
valid when periodic notification is selected.
Maintenance
Unit (Warning)
-
-
2 H 0 M
Sets whether to issue notifications for warnings related to maintenance
units (fuser unit, etc.).
This setting is only valid when notification upon occurrence is selected.
Maintenance
Unit (Warning)
-
-
ENABLE
Sets whether to issue notifications for warnings related to maintenance
units (fuser unit, etc.).
This setting is only valid when periodic notification is selected.
Maintenance
Unit (Error)
-
-
Immediate Sets whether to issue notifications for errors related to maintenance units
(fuser unit, etc.).
This setting is only valid when notification upon occurrence is selected.
Maintenance
Unit (Error)
-
-
ENABLE
Sets whether to issue notifications for errors related to maintenance units
(fuser unit, etc.).
This setting is only valid when periodic notification is selected.
Paper Supply
(Warning)
-
-
0 H 15 M
Sets whether to issue notifications for warnings related to paper.
This setting is only valid when notification upon occurrence is selected.
Paper Supply
(Warning)
-
-
ENABLE
Sets whether to issue notifications for warnings related to paper.
This setting is only valid when periodic notification is selected.
Paper Supply
(Error)
-
-
Immediate Sets whether to issue notifications for errors related to paper.
This setting is only valid when notification upon occurrence is selected.
Paper Supply
(Error)
-
-
ENABLE
Sets whether to issue notifications for errors related to paper.
This setting is only valid when periodic notification is selected.
Printing Paper
(Warning)
-
-
DISABLE
Sets whether to issue notifications for warnings related to paper feed.
This setting is only valid when notification upon occurrence is selected.
Printing Paper -
-
DISABLE
Sets whether to issue notifications for warnings related to paper feed.