H3C LS-3100-52P-OVS-H3 Operation Manual - page 1739
1-3
When you configure a Track object, the specified NQA test group and Reaction entry can be
nonexistent. In this case, the status of the configured Track object is Invalid.
Configuring Track-BFD Collaboration
Through the following configuration, you can establish the collaboration between the Track module and
BFD, which probes the link status and informs the Track module of the probe result.
Follow these steps to configure Track-BFD collaboration:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Create a Track object and
associate it with the BFD
session
track track-entry-number bfd
echo interface interface-type
interface-number remote ip
remote-ip local ip local-ip
Required
No Track object is created by
default.
Configuring Collaboration Between the Track Module and the
Application Modules
Configuring Track-VRRP Collaboration
Through the Track-VRRP collaboration, you can:
z
Monitor the upper link. If there is a fault on the upper link of the master of a VRRP group, hosts in
the LAN cannot access the external network through the master. In this case, the status of the
monitored Track object changes to Negative, and the priority of the master thus decreases by a
specified value, allowing a higher priority router in the VRRP group to become the master to
maintain proper communication between the hosts in the LAN and the external network.
z
Monitor the master on a backup. If there is a fault on the master, the backup working in the
switchover mode will switch to the master immediately to maintain normal communication.
Configuration prerequisites
Before configuring VRRP to monitor a Track object, you need to create a VRRP group on an interface
and configure the virtual IP address of the VRRP group.
Configuration procedure
Follow these steps to configure Track-VRRP collaboration:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter interface view
interface interface-type
interface-number
—