H3C LS-3100-52P-OVS-H3 Operation Manual - page 182
1-4
z
Provider A and Provider B are service provider network edge devices, which are interconnected
through configured trunk ports.
The configuration is required to satisfy the following requirements:
z
Geographically dispersed customer network access devices Customer A and Customer B can
implement consistent spanning tree calculation across the service provider network.
z
The destination multicast MAC address configured for BPDU tunnel frames is
0x0100-0CCD-CDD0.
Figure 1-2 Network diagram for BPDU tunneling configuration
Network
Provider A
Provider B
Customer A
Customer B
GE1/0/2
GE1/0/1
VLAN 2
VLAN 2
Configuration procedure
1) Configuration on Provider A
# Configure the destination multicast MAC address for BPDU tunnel frames as 0x0100-0CCD-CDD0.
[ProviderA] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 1/0/1 to transmit packets through VLAN 2.
[ProviderA] vlan 2
[ProviderA-vlan2] quit
[ProviderA] interface GigabitEthernet 1/0/1
[ProviderA-GigabitEthernet1/0/1] port access vlan 2
# Configure GigabitEthernet 1/0/1 to transmit BPDUs transparently.
[ProviderA-GigabitEthernet1/0/1] undo stp enable
[ProviderA-GigabitEthernet1/0/1] bpdu-tunnel dot1q stp
2) Configuration on Provider B
# Configure the destination multicast MAC address for BPDU tunnel frames as 0x0100-0CCD-CDD0.
[ProviderB] bpdu-tunnel tunnel-dmac 0100-0ccd-cdd0
# Configure GigabitEthernet 1/0/2 to transmit packets through VLAN 2.
[ProviderB] vlan 2
[ProviderB-vlan2] quit
[ProviderB] interface GigabitEthernet 1/0/2
[ProviderB-GigabitEthernet1/0/2] port access vlan 2
# Configure GigabitEthernet 1/0/2 to transmit BPDUs transparently.