H3C LS-3100-52P-OVS-H3 Operation Manual - page 231
1-11
Figure 1-5 Network diagram for MD configuration
Configuration procedure
1) Configuration on Device A (configuration on Device E is the same as that on Device A)
[DeviceA] cfd enable
[DeviceA] cfd md MD_A level 5
[DeviceA] cfd ma MA_MD_A md MD_A vlan 100
[DeviceA] cfd service-instance 1 md MD_A ma MA_MD_A
2) Configuration on Device C
[DeviceC] cfd enable
[DeviceC] cfd md MD_B level 3
[DeviceC] cfd ma MA_MD_B md MD_B vlan 100
[DeviceC] cfd service-instance 2 md MD_B ma MA_MD_B
3) Configuration on Device B (configuration on Device D is the same as that on Device B)
[DeviceB] cfd enable
[DeviceB] cfd md MD_A level 5
[DeviceB] cfd ma MA_MD_A md MD_A vlan 100
[DeviceB] cfd service-instance 1 md MD_A ma MA_MD_A
[DeviceB] cfd md MD_B level 3
[DeviceB] cfd ma MA_MD_B md MD_B vlan 100
[DeviceB] cfd service-instance 2 md MD_B ma MA_MD_B
After the above configuration, you can use the commands display cfd md, display cfd ma and
display cfd service-instance to verify your configuration.
Configuring MEP and Enabling CC on it
Network requirements
After finishing service instance configuration, you can start to design the MEPs.
z
MEPs are configured at the edge or border of MDs. Find the edge port of each MD.
z
Decide the MEP direction (inward-facing or outward-facing) on each edge port based on the MD
position.
z
Assign a unique ID to each MEP in an MA.