Qlogic 3200 Series User Manual - Command Summary
7–iSCSI Noninteractive Commands
Command Summary
7-2
SN0054667-00 G
The positional parameters vary, depending on the command option specified. For
example, to display an adapter’s configured settings, use the command option
-C, followed by the port instance number (positional parameter). In contrast, the
command for providing general information, -g, has no positional parameters.
In noninteractive mode, most changes made to the port instance become effective
immediately. This functionality sometimes causes the adapter to reset, as
specified in the command description. Ensure that the system is prepared for an
adapter reset before making changes.
The remainder of this chapter contains an alphabetical list of QConvergeConsole
CLI commands used in noninteractive mode.
Command Summary
This section lists the command line options in alphabetic order, and provides a
description of each.
CHAP Name Null-terminated CHAP name, which is sent by the port
instance when responding to the CHAP challenge
CHAP Secret CHAP secret, which is used by the port instance when gener-
ating the CHAP response
Boot Target The target ID of the target device from which to boot
Boot LUN The LUN of the boot device
NOTE
Commands are case-sensitive. For example, -g is not the same as -G.
Only one command line option per input file is valid.
adapter ports in the system. You can see this list with the command -i.
Table 7-1. Noninteractive Command Variables (Continued)
Variable
Definition