Qlogic 3200 Series User Manual - -Lcd
7–iSCSI Noninteractive Commands
-lcd (Display Configured Link Configuration)
SN0054667-00 G
7-15
You can view this information for a specific LUN or for all LUNs attached to the
selected target.
To list the LUN information, issue the -l command as follows:
-l <hba_port_inst> <target_ID> [LUN ID]
If you do not include the LUN ID parameter, all the LUNs on the specified target
are shown.
-lcd
(Display Configured Link Configuration)
To display the configured link settings, issue the -lcd command. Note that
because a system reset is required for changes in link configuration to take effect,
the settings shown here may be different than the operating link configuration.
To list configured link information, issue the -lcd command as follows:
-lcd <hba_port_inst>
-linkchap
(Assign a CHAP Entry to a Target)
To link a CHAP entry to a target, issue the -linkchap command as follows:
–linkchap <hba_port_inst> <chap number> <target_ID> [
Where TGTBCA is an optional parameter to turn BIDI CHAP authentication on or
off for this target connection.
For example, to link a CHAP entry 9 on port 2 to target 10 with BIDI CHAP turned
on, issue the following command:
-linkchap 2 9 10 TGTBCA on
This command does not reset the adapter.
-lp
(Display Local Prefix List [IPv6])
The IPv6 local prefix list is created based on prefix information from router
advertisements. Destination IP addresses containing these prefixes can be
reached directly, without going through an intermediate router.
To display the local prefix list, issue the -lp command as follows:
-lp <hba_port_inst>
-model
To view the adapter “model(s)” (board type[s]) in the system, issue the -model
command as follows:
-model [hba_port_inst]