Qlogic 3200 Series User Manual - page 350
11–Converged Network Adapter Interactive Commands
Transceiver Diagnostics Monitoring Interface (DMI) (-dmi)
11-116
SN0054667-00 G
2. Port 2 [Protocol(s): NIC iSCSI FCoE]
MAC Address: 00:0E:1E:04:95:EC
WWPN: 21-00-00-0E-1E-04-95-EF
Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
Please Enter Selection: 2
Transceiver Diagnostics Monitoring Interface (DMI)
1: General
2: Details
General
4. Adapter Diagnostics1. Converged Network Adapter9. Transceiver Diagnostics Monitoring Interface (DMI)
selection>1. General
From the Transceiver Diagnostics Monitoring Interface (DMI) menu, select the
General option to view basic DMI diagnostic information. For example:
------------------------------------------------------------------------------
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20
------------------------------------------------------------------------------
------------------------------------------------------------------------------
Media Information
------------------------------------------------------------------------------
Vendor: FINISAR CORP.
Type: 10G Base-SR
Part Number: FTLX8571D3BCL-QL
Speed: 10 Gbits/Sec
Revision: A
Serial Number: AH208K5
QLogic SFP Installed: Yes
------------------------------------------------------------------------------
Temperature Voltage Tx Bias Tx Power Rx Power
(C) (V) (mA) (mW) (mW)
-------------- ------- ------- -------- --------
Value 36.45 3.36 8.31 0.6040 0.6625
Status Normal Normal Normal Normal Normal
High Alarm 78.00 3.70 11.78 0.8318 1.0000
High Warning 73.00 3.60 10.80 0.6607 0.7943
Low Warning -8.00 3.00 5.00 0.3162 0.0158
Low Alarm -13.00 2.90 4.00 0.2512 0.0100