11–Converged Network Adapter Interactive Commands
Loopback Test
11-110
SN0054667-00 G
Display Test Parameters
4. Adapter Diagnostics1. Converged Network Adapter1. CNA Model6. Loopback Test
selection>2. FCoE1. Display Test Parameters
From the Loopback Test menu, select the Display Test Parameters option to
view the loopback test parameters. For example:
------------------------------------------------------------------------------
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20
------------------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Data Pattern : Random
Data Size (Bytes) : 8
Number of tests (1-65535): 10000
Test Increment(1-65535) : 1
Abort On Error : Ignore
Test Continuous : OFF
Loopback Type : Special Echo FCoE Loopback (252) in size
------------------------------------------------------------------------
Reset Test Parameters
4. Adapter Diagnostics1. Converged Network Adapter1. CNA Model6. Loopback Test
selection>2. FCoE2. Reset Test Parameters
From the Loopback Test menu, select the Reset Test Parameters option to reset
the loopback test parameters to their default values.
lists the default
loopback test values.
Table 11-1. Default Loopback Test Parameter Values
Parameter
Default Value
Data Pattern
Random
Data Size (Bytes)
8
Number of tests
10,000
Test Increment
1
Abort On Error
Ignore
Test Continuous
OFF
Loopback Type
Special Echo FCoE Loopback (252) in size