Qlogic 3200 Series User Manual - -Save
7–iSCSI Noninteractive Commands
-save (Save Host Configuration)
7-24
SN0054667-00 G
-save
(Save Host Configuration)
To save the configuration (in XML) of all adapters detected, issue the -save
command as follows:
-save <file_name>
-sbootcode
(Set Secondary Boot Target Information)
To set the secondary boot target and LUN, issue the -sbootcode command as
follows:
-sbootcode <hba_port_inst> <Boot Target> <Boot LUN>
Issuing this command saves the configuration data to an XML file portable to all
platforms supported by iSCSI. This command is not active for PPC.
For primary boot code, see
“-pbootcode (Set Primary Boot Target Information)”
-sbootcodecid
(Set Alternative Client ID)
To set the alternative client ID (seven characters maximum), issue the
-sbootcodecid command as follows:
-sbootcodecid <hba_port_inst> <Alternative Client ID>
This command is not active for the PPC.
-sdmrc
To return the SDM library return code, issue the -sdmrc command as follows:
-sdmrc [simple_pattern]
When [
simple_pattern
]
is specified, only the lines containing that string are
printed.
-stadd
(Add a Send Target)
To add a send target for discovery, issue the -stadd command as follows:
-stadd
<hba_port_inst> <ip address> [chapIndex] [<TGBCA> <value>]
Where <value> can be on or off; on causes the send target login to require
bidirectional CHAP.