Oce VarioPrint 5000 Operating Manual - page 241
7.3.2 Replacing the sealing blade (cleaning)
A29246-X17-X-4-7680 / do701.fm
231
7.3.2 Replacing the sealing blade (cleaning)
900,000 A4 pages can be printed with the sealing blade. After that,
a warning message
appears on the operator panel. If it is not replaced during the warning period of another
150,000 A4 pages, the printing system stops and an error message is displayed. The blade
must be replaced at this point.
The procedure for replacing the sealing blade is the same for the upper and lower cleaning
stations. The following section shows the procedure for the upper cleaning station.
Removing the sealing blade
Proceed as follows:
1.
Press the
2.
Select the print unit concerned and "sealing blade (cleaning)" on the operator panel
in the
Press the
3.
Open the center doors.
Caution
If you pull out the cleaning station too sharply and quickly, you could pull it beyond
its stop point causing it to drop to the floor. There is a danger of injury to you and of
damage to the cleaning station.
Always slide the cleaning station slowly and evenly to its stop point on the guide rail
(reference speed max. 0.5 m/s).
4.
Lift up the handle and pull the cleaning
station slowly and evenly out of the
system.