Oce VarioPrint 5000 Operating Manual - page 339
8.4.3.8 Displaced printing
A29246-X17-X-4-7680 / do805.fm
329
8.4.3.8 Displaced printing
Cleaning corotron soiled
Clean wire
6.5 Cleaning corotron
wires if an error occurs
>>> page 196
Replace corotron cartridge
7.3.9 Replacing the
cleaning corotron
cartridge >>> page 268
Luminescentstrips in the
developer stationsoiled
Clean luminescentstrips in the
developer station
6.3.2 Cleaning the
developer station >>>
page 166
Luminescentstrips in the
charge station soiled
(memory)
Clean luminescentstrips in the
charge station
6.3.3 Cleaning the
charge station >>>
page 168
Edge of cleaning blade (cleaning)
faulty
Turn cleaning blade (cleaning) or
replace
7.3.1 Replacing or
turning the cleaning
blade (cleaning) >>>
page 227
Photoconductor drum soiled or
damaged
Possibly replace photoconductor
drum
7.3.10 Replace
photoconductor drum
>>> page 270
Developer station soiled
Cleaning the developer station
6.3.2 Cleaning the
developer station >>>
page 166
Paper damp and undulating
Store the paper as directed
Insert new paper
1.6 Other documents
>>> page 12
5.4 Refilling paper >>>
page 93
Paper damaged
Insert new paper
5.4 Refilling paper >>>
page 93
Cause
Correction
See section
Paper cut incorrectly or damaged
Insert new paper
5.4 Refilling paper >>>
page 93
Cause
Correction
See section