NEC Univerge SV8100 Programming Manual - page 178
Issue 1.0
UNIVERGE SV8100
2 - 138
Program 14 : Trunk, Basic Setup
Description
Use Program 14-02 : Analog Trunk Data Setup to set the basic options for each
analog trunk port. Refer to the table below for a description of each option, its range
and default setting.
Program 14 : Trunk, Basic Setup
14-02 : Analog Trunk Data Setup
Level:
IN
Input Data
Trunk Port Number
001~200
Item
No.
Item
Input Data
Default
Related
Program
01
Signaling Type (DP/DTMF)
This option sets the signaling type for
the trunk.
0 = Dial Pulse (10
PPS)
1 = Dial Pulse (20
PPS)
2 = DTMF
2
02
Ring Detect Type
This option sets Extended Ring Detect
or Immediate Ring Detect for the trunk.
For T1 loop/ground start trunks, this
option must be set to 1 for the trunks to
ring and light correctly.
0 = Normal/delayed
1 = Immediate
Ringing
1
03
Flash Type
This option selects the flash type (open
loop flash or ground). Always set this
option for open loop flash.
0 = Open Loop Flash
1 = Ground
0
04
Hooking Type
This option lets you use Flash for
Timed Flash (Program 81-01-14) or
Disconnect (Program 81-01-15). (A
user implements Flash by pressing the
FLASH key while on a trunk call.)
0 = Timed Flash
(Hooking)
1 = Disconnect (Cut)
0
81-10-07
81-10-08
05
Dial Tone Detection for Manually
Accessed Trunks
Use this option enable/disable dial tone
detection for directly accessed trunks.
If disabled, the system outdials on the
trunks without monitoring for dial tone.
0 = Dial Tone
Detection Not
Used
1 = Dial Tone
Detection Used
0
21-01-04