NEC Univerge SV8100 Programming Manual - page 658
Issue 1.0
UNIVERGE SV8100
2 - 618
Program 81 : Basic Hardware Setup for Trunk
14
Ringing Signal Detection Time
(E&M)
1~250
(8ms ~ 2000ms)
10
80ms
15
Ringing Signal Detection Time
(OPX)
1~250
(8ms ~ 2000ms)
10
80ms
16
Ringing Signal Stop Detection
Time (Loop)
1~255
(100ms ~ 25500ms)
50
5000ms
17
Ringing Signal Stop Detection
Time (Ground)
1~255
(100ms ~ 25500ms)
50
5000ms
18
Ringing Signal Stop Detection
Time (DID)
1~255
(100ms ~ 25500ms)
50
5000ms
19
Ringing Signal Stop Detection
Time (E&M)
1~255
(100ms ~ 25500ms)
50
5000ms
20
Ringing Signal Stop Detection
Time (OPX)
1~255
(100ms ~ 25500ms)
50
5000ms
21
Loop Current Detection Time
(Loop)
1~250
(4ms ~ 1000ms)
40
160ms
22
Loop Current Detection Time
(Ground)
1~250
(4ms ~ 1000ms)
40
160ms
23
Loop Current Detection Time
(DID)
1~250
(4ms ~ 1000ms)
40
160ms
24
Loop Current Detection Time
(E&M)
1~250
(4ms ~ 1000ms)
40
160ms
25
Loop Current Detection Time
(OPX)
1~250
(4ms ~ 1000ms)
40
160ms
26
DP Break Send Time (ALL)
1~250
(4ms ~ 1000ms)
15
60ms
27
DP Make Send Time (ALL)
1~250
(4ms ~ 1000ms)
10
40ms
28
DP InterDigit Send Time (ALL)
1~255
(100ms ~ 25500ms)
7
700ms
29
HookFlash Send Time (Loop)
1~255
(100ms ~ 25500ms)
5
500ms
30
HookFlash Send Time (Ground)
1~255
(100ms ~ 25500ms )
5
500ms
31
HookFlash Send Time (DID)
1~255
(100ms ~ 25500ms )
5
500ms
32
HookFlash Send Time (E&M)
1~255
(100ms ~ 25500ms )
5
500ms
Item
Name
Input Data
Default