34
--- Not Used ---
35
--- Not Used ---
36
The Maximum FAX
Transmission Rate
0 = V.27ter, 2400bps
1 = V.27ter, 4800bps
2 = V.29, 7200bps
3 = V.29, 9600bps
4 = V.17, 12000bps
5 = V.17, 14400bps
5
37
FAX FIFO Considering Delay
Time
0~600ms
300
38
Size of FAX Packet
20~48 bytes
20
39
FAX Modem Transmission
Level
0~13 (0dBm ~ -13dBm)
9
40
FAX Modem Carrier Signal
Detection Threshold
0 = -26dBm
1 = -33dBm
2 = -43dBm
1
41
FAX Communication no
Communication Time-Out
10~32000 seconds
30
43
High-speed Signal Data (fax
picture signal) Packet Length
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
4
44
Low-speed Signal Data (FAX
Procedure Signal)
0~5
0
45
High-speed Signal Data (FAX
Procedure Signal)
0~2
0
46
TCF Operation Setting
1 = Training signal (TCF) of the fax
is locally generated and checked.
2 = Training signal (TCF) of the fax
is sent over the network
.
1
47
The Maximum, Low-speed
Signal Data (Size of Packet)
1~65535 bytes
1
48
Network Transmission Time-
out
10~32000 seconds
150
49
Eflag Beginning Timer
0~65535
2600
50
Eflag Stop Timer
0~65535
2300
51
The Former Line Substitution
of Scanning Line
(FAX Relay item)
0 = Disable
1 = Enable
1
Input Data
Item
No.
Item
Input Data
Default