Description
Use Program 90-20 : Traffic Report Data Setup to define the details of the traffic
report.
Program 90 : Maintenance Program
90-20 : Traffic Report Data Setup
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
01
Call Traffic Output
0 = Not Measured
1 = Measure
0
02
--- Not Used ---
03
All Line Busy Output
0 = Not Detected
1~256
(Report when the data reaches the
defined value)
0
04
DTMF Receiver Busy Output
0 = Not Detected
1~256
(Report when the data reaches the
defined value)
0
05
Dial Tone Detector Busy Output
0 = Not Detected
1~256
(Report when the data reaches the
defined value)
0
06
Caller ID Receiver Busy Output
0 = Not Detected
1~256
(Report when the data reaches the
defined value)
0
07
Voice Mail Channel All Busy Output
0 = Not Detected
1~256
(Report when the data reaches the
defined value)
0
08
ACD Operator All Busy Output
0 = Not Detected
1~256
(Report when the data reaches the
defined value)
0