NEC Univerge SV8100 Programming Manual - page 748
Issue 1.0
UNIVERGE SV8100
2 - 708
Program 90 : Maintenance Program
13
0
0
Charge
Management
Link Error
The link with the charge
management device came
off.
1. Problem of
wiring to connect
main device with
charge
management
device.
2. Problem of PC.
1. It is confirmed that
there is no problem in
wiring to connect a
main device with the
charge management
device. (Whether ping
passes for LAN
connection is
confirmed.)
2. Restart the charge
management software.
3. Reboot PC, and start
the charge
management software.
When the
connection
returns
normally, the
error is
recover.
ERR
REC
14
0
0
LAN Link
Error
The link with LAN on
CD-CP00-US came off.
• LAN cable
defective.
• Connected HUB
broken.
• Defect of
CD-CP00-US
Confirm the operation
of LAN connector, LAN
cable, and HUB again.
When the
connection
returns
normally, the
error is
recover.
ERR
REC
15
0
0
Network Keep
Alive
1. The network connection
has been cut.
2. Network Keep Alive
restoration.
3. Response notification on
network Keep Alive.
• LAN cable is
defective.
• Net side trouble.
• Packet block by
firewall.
• Repetition of IP
address.
Confirm whether the
defect is on the Network
side.
Confirm the settings of
HUB and the router,
etc.
When the
connection
returns
normally, the
error is
recovered.
ERR
REC
WAR
16
0
0
SMDR Link
17~28
--- Reserved ---
29
0
0
Charge
Management
Buffer full
The temporary buffer for
the charge management in
main device was
overflowed, and a part of
unoutput charge data
disappeared because it
was not able to output the
charge management data.
1. The charge data
is printed and not
deleted at the
simple charge
management.
2. The charge data
is not output to PC
for the charge
management
software.
1. Please print and
delete the charge data
at the simple charge
management.
2. Please connect the
charge management
software for the charge
management software
and output the charge
data.
When the
output is
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
ERR
REC
30
2
0
SMDR Buffer
full
The temporary buffer for
SMDR in main device was
overflowed, and a part of
unoutput SMDR data
disappeared because it
was not able to output
SMDR data.
1. Problem of
wiring to connect
main device with
PC.
2. Problem of PC.
1. Please confirm
whether there is
problem in wiring to
connect a main device
with PC.
2. Please execute the
reactivation of PC.
When the
output is
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.
ERR
REC
31~34
--- Reserved ---
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status