NEC Univerge SV8100 Programming Manual - page 682
Issue 1.0
UNIVERGE SV8100
2 - 642
Program 82 : Basic Hardware Setup for Extension
Description
Use Program 82-12 : OPX Initial Data Setup to define the various initial data for
OPX packages.
Conditions
None
Feature Cross Reference
None
Program 82 : Basic Hardware Setup for Extension
82-12 : OPX Initial Data Setup
Level:
IN
Input Data
Item
No.
Item
Description
Input
Default
01
Bounce Protect Time
Specify a time for detection of a valid
off-Hook indication that is long enough
to prevent an unintentional bounce of
the receiver from being detected as a
new Off-Hook indication from a single
line telephone.
0 = No Setting
1~15 = 100ms~1.5sec
3
02
HookFlash Start Time
Specify the minimum hookflash time
from a single line telephone or analog
Voice Mail system before it is detected
as the beginning of a valid hookflash.
0 = 40ms
1~15 = 90ms~790ms
5
03
HookFlash End Time
Specify the maximum hookflash
duration from a single line telephone to
receive a second dial tone.
0 = HST+0ms
1~15=HST+100ms~HST+1500ms
(HST=Hookflash Start Time)
7