NEC Univerge SV8100 Programming Manual - 10-03 : Etu Setup
UNIVERGE SV8100
Issue 1.0
Programming Manual
2 - 5
Description
Use Program 10-03 : ETUSetup to setup and confirm the Basic Configuration data
for each blade. When changing a defined terminal type, first set the type to 0 and then
plug the new device in to have the system automatically define it or you may have to
reseat the blade.
The items highlighted in
gray
are read only and cannot be changed.
Input Data
For CNF PKG Setup
For DLCA PKG Setup
Program 10 : System Configuration Setup
10-03 : ETU Setup
Level:
IN
Physical Port Number
01~16
Item
No.
Item
Input Data
Default
01
Logical Port Number
0~256
0
Physical Port Number
01~16
Item
No.
Item
Input Data
Default
01
Terminal Type (B1)
0 = Not set
1 = Multiline Terminal
2 = SLT Adapter
3 = Bluetooth Cordless Handset
6 = PGD(2)-U10 ADP (Paging)
7 = PGD(2)-U10 ADP (Tone Ringer)
8 = PGD(2)-U10 ADP (Door Box)
9 = PGD(2)-U10 ADP (ACI)
10 = DSS Console
11 = --- Not Used ---
0