NEC Univerge SV8100 Programming Manual - page 752
Issue 1.0
UNIVERGE SV8100
2 - 712
Program 90 : Maintenance Program
81
2
0
NetLink call
trouble
information.
The trouble occurred by
the NetLink relation.
• The DSP resource was
not able to be acquired at
incoming/outgoing.
• DSP of
PZ-32IPLA was not
able to be acquired.
Reconfirm wiring and
the system data setting.
Please inquire an
uncertain point of the
maker.
WAR
82
2
0
NetLink
Virtual Slot
accommod.
error.
The trouble occurred by
virtual Slot relation.
• It exceeded it to the slot
accommodation upper
bound.
• It failed in making a virtual
slot.
• It exceeds it to the
number of slot
accommodation in
the entire system of
NetLink.
Confirm whether to
exceed the slot number
upper bound.
Please inquire an
uncertain point of the
maker.
WAR
83
2
0
NetLink
Communicati
on Error.
The communication error
occurred by NetLink.
• The checksum error
occurred.
• The index error occurred.
• The setting of the
router is wrong.
• It is an error to the
link of LAN.
• Net side trouble.
Reconfirm LAN
connector and wiring.
Please inquire an
uncertain point of the
maker.
WAR
84
2
0
NetLink
License Error
The error related to the
license occurred by
NetLink.
• The expiration date of the
license approaches.
• The license was nullified.
• The expiration
date of a temporary
license
approaches.
• A temporary
license was
nullified.
Confirm license
information.
Please inquire an
uncertain point of the
maker.
WAR
85
2
0
NetLink node
connection
refusal.
The connection of
Secondary was refused in
NetLink.
• SystemID overlaps.
• SystemID is illegal.
• The license is insufficient.
• It is memory shortage.
• Repetition setting
of SystemID.
• SystemID is
illegal.
• The number of
licenses is lack.
• The system
memory is
insufficient.
Confirm the setting and
license information on
SystemID.
Please inquire an
uncertain point of the
maker.
WAR
86
2
0
Data base
replication
fail.
Because the versions of
DB is different, replication
cannot be executed
between Primary and
Secondary.
• The versions of
data bases
between Primary
and Secondary is
different.
Confirm the versions of
data bases of Primary
and Secondary by PC
PRO.
Please inquire an
uncertain point of the
maker.
WAR
87
2
0
Data base
replication
fail.
Because the error occurred
in the communication
between Primary and
Secondary, replication
cannot be executed.
The link of LAN
between Primary
and Secondary was
disconnected.
Confirm the link of LAN
between Primary and
Secondary.
WAR
88
2
0
NetLink
phase shift.
Operation began as
Primary.
• Operation began
as Primary.
No action is necessary.
INF
89
2
0
NetLink
phase shift.
Operation began as
Secondary.
• Operation began
as Secondary.
No action is necessary.
INF
90
2
0
NetLink
phase shift.
It shifted to the node
search mode.
• It shifted to the
node search mode.
No action is necessary.
INF
91
2
0
Primary auto-
integration.
Primary auto-integration
function operated.
• Primary auto-
integration function
operated.
No action is necessary.
INF
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status