NEC Univerge SV8100 Programming Manual - page 292
Issue 1.0
UNIVERGE SV8100
2 - 252
Program 20 : System Option Setup
15
Delayed Call Forwarding Time (Call Forward
No Answer)
If activated at an extension, Delayed Call
Forwarding occurs after this time. This also sets
how long a Transferred call waits at an
extension forwarded to Voice Mail before
routing to the called extension mailbox.
0~64800 seconds
10 seconds
24-02-03
16
Transfer Recall Time
An unanswered transferred call recalls after this
time to the extension that initially transferred it.
0~64800 seconds
30 seconds
24-02-04
17
DID/DISA No Answer Time (Disconnect or
IRG or VM)
A VRS/DISA caller can ring an extension for
this time before the system sets the call as a
Ring No Answer. After this time expires, the
call follows the programmed Ring No Answer
routing (set in Program 25-03 and 25-04).
0~64800 seconds
0 seconds
25-07-02
18
Disconnect after Re-transfer to IRG
0~64800 seconds
60 seconds
25-07-03
19
Long Conversation Warning Tone Time
(Trunk to Trunk)
Determine the time a DISA caller or any
trunk-to-trunk (such as Tandem Trunking)
conversation can last before the Long
Conversation tone is heard
0~64800 seconds
3600 seconds
25-07-07
20
Long Conversation Disconnect (Trunk to
Trunk)
This time determines how long the system waits
before disconnecting a DISA caller or any
trunk-to-trunk (such as Tandem Trunking)
conversation call after the Long Conversation
tone is heard.
0~64800 seconds
10 seconds
25-07-08
21
DISA Internal Paging Time
This is the maximum length of an Internal Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call.
0~64800 seconds
30 seconds
25-07-09
22
DISA External Paging Time
This is the maximum length of an External Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call.
0~64800 seconds
30 seconds
25-07-10
23
Page Announcement Duration
This timer sets the maximum length of Page
announcements. (Affects External Paging only)
0~64800 seconds
1200 seconds
31-01-02
Item
No.
Item
Input Data
Default
Related