NEC Univerge SV8100 Programming Manual - 20-18 : Service Tone Timers
UNIVERGE SV8100
Issue 1.0
Programming Manual
2 - 237
Description
Use Program 20-18 : Service Tone Timers to set the values for the system service
tone timers. Refer to the following chart for a description of each option, its range and
default setting.
Program 20 : System Option Setup
20-18 : Service Tone Timers
Level:
IN
Input Data
Item
No.
Item
Input
Data
Default
Description
Related
Program
01
Extension Dial Tone
Time
0~64800
seconds
30
After getting Intercom dial tone,
a telephone user has this time
to dial the first digit of the
Intercom call.
02
Busy Tone Timer
0~64800
seconds
15
03
Congestion Tone
0~64800
seconds
10
A Busy Tone when system
resources run short. (such as
DTMF receiver resources).
04
Call Waiting Tone
Timer
0~64800
seconds
10
This option sets the time
between Call Waiting tones.
This timer also sets the time
between Off-Hook Signaling
alerts.
05
Multiline Confirmation
Tone
0~64800
seconds
10
06
Interval of Call
Waiting Tone
0~64800
seconds
10
07
Intrusion Tone Repeat
Time
0~64800
seconds
0
After a call is interrupted (such
as Barge-In, Voice Mail
Conversation Recording, or
Voice Over), the system
repeats the Intrusion Tone after
this time. Normally, you should
enter 0 to disable this time.
08
Conference Tone
Interval
0~64800
seconds
0
09
Warning Beep Tone
Signaling Interval
0~64800
seconds
60
14-01-18