Program 16 : Department Group Setup
04
Hunting Mode
Use this option to set the action
taken when a call reaches the
last extension in the Department
Group (0=hunting stopped,
1 =hunting repeats with circular
routing through the Department
Group).
0 = Last extension is
called and hunting
is stopped
1 = Circular
0
05
Extension Group All Ring
Mode Operation
Determine whether calls ringing
a Department Group should ring
all extensions in the group
simultaneously automatically or
manually when using the
service code defined in Program
11-12-09.
When set to (1)
Automatic, only ICM
Calls and DID Calls will
ring all the stations in the
Department Group.
0 = Manual
1 = Automatic
0
11-16-10
06
STG Withdraw Mode
0 = Disable (Camp
On)
1 = Enable (Overflow
Mode)
0
07
Call Recall Restriction for
STG
Determine whether or not an
unanswered call transferred to a
Department Group should recall
the extension from which it was
transferred.
0 = Disable (Recall)
1 = Enable (No
Recall)
0
08
--- Not Used ---
09
Department Hunting No
Answer Time
Set how long a call rings a
Department group extension
before hunting occurs.
0~64800 seconds
15
10
Enhanced Hunt Type
Set the type of hunting for each
Extension (Department) Group.
0 = No queuing
1 = Hunting When
Busy
2 = Hunting When
Not Answered
3 = Hunting When
Busy or No
Answer
0
Item
No.
Item
Input Data
Default
Related
Program