NEC Univerge SV8100 Programming Manual - page 643
Programming Manual
2 - 603
Program
81
Description
Use Program 81-01 : COT Initial Data Setup
to define the various basic data
parameters for the COT Unit.
Program 81 : Basic Hardware Setup for Trunk
81-01 : COT Initial Data Setup
Level:
MF
Input Data
Item
No.
Item
Input Data
Default
01
PCM Encoding Method
Specification
0 = u-law
1 = A-law
0
02
Loop Current Detection Time
1~255
(8~2040ms)
75
(600ms)
03
Clear Signal (Open Loop)
Detection Time
1~255
(8~2040ms)
38
(304ms)
04
Ringing Signal Detection Minimum
Time
1~255
(8~2040ms)
13
(104ms)
05
Single Ringing Detection Minimum
Time
0~255
(0,8~2040ms)
82
(656ms)
06
Double Ringing Detection
Minimum Off Time
0~255
(0,8~2040ms)
13
(104ms)
07
Double Ringing Detection
Maximum Off Time
0~255
(0,8~2040ms)
50
(400ms)
08
Ringing Signal not Detection
Minimum
1~255
(8~2040ms)
88
(704ms)
09
Time Ringing Signal Stop
Detection Time
1~255
(64~16320ms)
94
(6016ms)
10
Continuous Ringing Minimum
Time
0~255
(0,8~2040ms)
38
(304ms)
11
Continuous Ringing Maximum
Time
0-255
(0,8~2040ms)
88
(704ms)
12
Caller ID Detection Time
0~255
(0~16320ms)
0
(0ms)