NEC Univerge SV8100 Programming Manual - page 747
UNIVERGE SV8100
Issue 1.0
Programming Manual
2 - 707
6
0
0
Blocking
The link of terminals
connected with the ESI
package came off.
• Breakdown of
terminal.
• Faulty wiring and
wiring
determination.
• External noise.
• Breakdown of ESI
package.
Confirm the terminal
connected with same
ESI. If they work
normally, confirm the
breakdown or the wiring
for the terminal.
Exchange the terminal
that doesn't work and
the working terminal,
and confirm it’s
working. An external
factor of the noise etc.
is thought.
Please reconfirm wiring
and the installation,etc.
Please inquire of the
manufacturer when the
problem occurs after it
confirms it.
The error is
recovered
when
reconnecting
or exchanging
it.
ERR
REC
7
1
0
Power failure
The supply of the
commercial power
stopped.
• The power cable
came off.
• Power failure
• The power supply
unit broke down.
Confirm the power
supply outlet when the
commercial power has
not stopped.
Please inquire of the
manufacturer when the
problem occurs.
When the
commercial
power is
restored, the
error is
recovered.
ERR
REC
8
1
0
RAM Backup
Battery Error
RAM backup battery on the
CD-CP00-US blade is
unplugged or defective.
Check the battery
connector. If it is
connected correctly,
replace the battery.
The error is
recovered
once the
battery is
replaced.
ERR
REC
9
--- Reserved ---
10
0
0
ISDN Link
Error
Layer1 link of ISDN lines
came off.
• Connected
determination of
main device and
ISDN line
• Breakdown of
DSU
• The setting of
PRG10-03 is not
corresponding to
an actual line.
Confirm the data of
PRG10-03.
Reconfirm wiring and
the installation of DSU.
Please inquire of the
manufacturer when the
problem occurs after it
confirms it.
When the
connection
returns
normally, the
error is
recover.
ERR
REC
11
0
0
CTI Link Error
The link with the CTI server
came off.
• LAN cable
defective.
• Connected HUB
broken.
• The CTI server
doesn't start
normally.
Please reconfirm the
CTI server, wiring, and
the connection.
Please inquire of the
manufacturer when the
problem occurs after it
confirms it.
When the
connection
returns
normally, the
error is
recover.
ERR
REC
12
0
0
ACD MIS Link
Error
The link with ACD MIS
client PC came off.
• LAN cable
defective.
• Connected HUB
broken.
• The CTI server
doesn't start
normally.
Please confirm ACD
MIS client PC and
connected part.
Please inquire of the
manufacturer when the
problem occurs after it
confirms it.
When the
connection
returns
normally, the
error is
recover.
ERR
REC
Table 2-20 Description of Alarm (Continued)
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status