NEC Univerge SV8100 Programming Manual - 90-10 : System Alarm Setup
UNIVERGE SV8100
Issue 1.0
Programming Manual
2 - 705
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm is displayed to a multiline terminal and whether or not the alarm information
is reported to the pre-defined destination.
Program 90 : Maintenance Program
90-10 : System Alarm Setup
Level:
IN
Input Data
Alarm Number
001~100
Item
No.
Item
Input Data
01
Alarm Type
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
02
Report
0 = Not Report (No autodial)
1 = Report (autodial)
Table 2-20 Description of Alarm
Alarm
No.
Type
Report
Name
Content of Alarm
Cause
Action
Recovery
Alarm
Status
1
2
0
PKG Initialize
Error.
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
1. PKG not inserted
firmly.
2. PKG was
removed, but not
reinserted firmly.
3. Old PKG data
still reported due to
no initialization.
1. Insert PKG firmly.
2. Insert PKG firmly.
3. Delete slot
information in
PRG 90-05 and reinsert
the PKG.
Upon
initialization,
the PKG is
recognized.
ERR
REC
2
2
0
PKG Mount-
ing Error
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.
1.The package is
half.
2.The package is
out of order.
1.Please insert the
package firmly.
2.Please try again after
initializing the system
data once when LED
doesn't blink normally.
3.Exchange of
packages.
When the unit
is
reconfirmed,
the error is
recovered.