Program 15 : Extension, Basic Setup
Description
Use Program 15-22 : Mobile Extension Setup to set the system information for the
Mobile Extension feature.
Conditions
None
Feature Cross Reference
None
Program 15 : Extension, Basic Setup
15-22 : Mobile Extension Setup
Level:
IN
Input Data
Extension Number
Up to eight digits
Item
No.
Item
Input Data
Default
01
Mobile Extension Target
Setup
Set which Speed Dial bin
is used to call when the
Mobile extension is
called.
0~1999 (0 = No setting/1~1999 = target of mobile
extension)
0
02
Connect Confirmation
Select when a
confirmation (dial ) is
required to allow the call
to cut over to the called
mobile number.
0 = Always
1 = On Analog Line
2 = Never
0
03
Trunk Access Code
Select if the Normal (0) or
Individual (1) Trunk
access is used when
making the call to the
mobile number.
0 = Use normal trunk access code (11-09-01)
1 = Use individual trunk access code (11-09-02)
0