Description
Use Program 10-20 : LAN Setup for External Equipment to define the TCP port/
address/etc. for communicating to external equipment.
Program 10 : System Configuration Setup
10-20 : LAN Setup for External Equipment
Level:
IN
Input Data
Type of External Equipment
1
= CTI Server
2
= ACD MIS
3
= Not Used
4
= Networking System
5
= SMDR Output
6
= DIM
Output
7
= Reserved
8
= Reserved
9
= 1st Party CTI
10 = ACD Agent Control
11 = O&M Server
12 = Traffic Report Output
13 = Room Data Output for Hotel
Service
Item
No.
Item
Input Data
Default
01
TCP Port
0~65535
External Device 1 (CTI Server) = 0
External Device 2 (ACD MIS) = 4000
External Device 5 (SMDR Output) = 0
External Device 6 (DIM Output) = 0
External Device 11 (O&M Server) = 8010
External Device 12 (Traffic Report Output) = 0
External Device 13 (Room Data Output for
Hotel Service) = 0
03
Keep Alive Time
1~255 (sec)
30