2 - 594
Program 80 : Basic Hardware Setup for System
Default
Conditions
None
Feature Cross Reference
None
04
No Tone Time
0~255 (30+30~7680ms)
(0 =not detect)
1~255 = 60~7680ms.
The formula is 30+30N.
When set to N=1, it means 30+30*1=60
When set to N=255, it means
30+30*255=7680
05
Pulse Count
1~255
06
ON Minimum Time
1~255 (30+30~7680ms)
07
ON Maximum Time
0~255 (30+30~7680ms)
08
OFF Minimum Time
1~255 (30+30~7680ms)
09
OFF Maximum Time
0~255 (30+30~7680ms)
12
Frequency No. 1
1~8 (Frequency Table No. set by 80-07)
13
Frequency No. 2
1~8 (Frequency Table No. set by 80-07)
Item No
Item
Input Data
Item
Name
Type 1 (DT)
Type 2 (BT)
Type 3 (RBT)
Type 4
Type 5
1
Detect Level
0 (-25dBm)
0 (-25dBm)
0 (-25dBm)
0
0
2
Min. detect
level
15 (-25dBm)
15 (-25dBm)
15 (-25dBm)
0
0
3
S/N ratio
4 (-20dB)
4 (-20dB)
4 (-20dB)
0
0
4
No tone time
132 (3990ms)
132 (3990ms)
132 (3990ms)
0
0
5
Pulse Count
1
1
1
0
0
6
ON min. time
9 (300ms)
12(390ms)
25 (780ms)
0
0
7
ON max. time
0 20(630ms)
40
(1230ms)
0
0
8
OFF min. time
1 (60ms)
12(390ms)
83 (2520ms)
0
0
9
OFF max. time
1 (60ms)
20(630ms)
115 (3480ms)
0
0