NEC Univerge SV8100 Programming Manual - Program 51 : Netlink Service
Issue 1.0
UNIVERGE SV8100
2 - 568
Program 51 : NetLink Service
Description
Use Program 51-05 : NetLink Timer Settings to set the various timers within the
NetLink system.
Program 51 : NetLink Service
51-05 : NetLink Timer Settings
Level:
IN
Item
No.
Item
Input Data
Default
01
Keep Alive Sending Interval
This is the Keep Alive timer sending interval
from the Secondary system to confirm
communication with the Primary system.
1~3600
5
02
Keep Alive Response Waiting Time
This is the time interval the Secondary system
waits for a response from the Primary system
before cutting off communication.
0, 5~10800
(0 = infinity)
0
03
Primary Search Packet Sending Interval
While searching the Primary system, the system
sends a packet at this interval.
1~3600
5
04
Primary Search Time Maximum Value
Total time of Primary system seek time.
5~10800
20
05
Top Priority Primary Detection Packet
Sending Interval
When current Primary system is not Top Priority
Primary System, the system sends packet to
check if Top Priority System exists.
1~3600
10
06
Primary Compulsion Specification Trial
Maximum Time
When the forced change Primary command is
executed, the system will search the new
Primary system for this amount of time.
1~10800
30
07
Socket Refresh Time
For some reason, the IP connection may
become unstable. Then keep-alive function does
not work. To avoid this, if there is no data traffic
for this time, the socket is refreshed.
20~3600
40