Description
Use Program 20-01 : System Options to set various system options.
Program 20 : System Option Setup
20-01 : System Options
Level:
IN
Input Data
Item
No.
Item
Input Data
Default
Description
Related
Program
01
Operator Access
Mode
0 = Step Call
1 = Circular
0
Use this program to set up priority of
a call when calling an operator
telephone.
20-17
02
Text Message Mode
0 = Call mode
1 = No Answer/
Busy mode
1
Use this program to select the mode
when calling the telephone which set
up the text message.
11-11-14
15-07-08
04
--- Not Used ---
05
DTMF Receive
Active Time
0~64800 seconds
10
For OPXs, analog telephones and
certain analog trunks (like DISA), the
system attaches a DTMF receiver to
the port for this interval. The system
releases the receiver after the
interval expires.
25-07-01
06
Alarm Duration
0~64800 seconds
30
This time sets the duration of the
alarm signal.
11-12-05
07
Callback Ring
Duration Time
0~64800 seconds
15
Callback rings an extension for this
time.
11-12-05
15-07-35
08
Trunk Queuing
Callback Time
0~64800 seconds
15
Trunk Queuing callback rings an
extension for this time.
11-12-05
15-07-35
09
Callback/Trunk
Queuing Cancel
Time
0~64800 seconds
64800
The system cancels an extension
Callback or Trunk Queueing request
after this time.
11-12-05
15-07-35
10
Trunk Guard Timer
0~64800 seconds
1
The amount of time the system waits
to seize the next outside line after
the system releases an outside line.
12
Telephone/Web Pro
Logout Time
1~84600 seconds
(84600sec =
1 day)
900
The system automatically logs out of
a Telephone/Web Pro session after
inactivity lasting this time.