NEC Univerge SV8100 Programming Manual - page 290
Issue 1.0
UNIVERGE SV8100
2 - 250
Program 20 : System Option Setup
Description
Use Program 20-31 : Timer Class Timer Assignment to assign values to the timers
on a class of service basis.
Program 20 : System Option Setup
20-31 : Timer Class Timer Assignment
Level:
IN
Input Data
Timer Class Number
0~15
Item
No.
Item
Input Data
Default
Related
Programming
01
Trunk Queuing Callback Duration Time
Trunk Queuing Callback rings an extension for
this amount of time
0~64800 seconds
15 seconds
20-01-08
02
Callback / Trunk Queuing Cancel Time
The system cancels an extension Callback or
Trunk Queueing request after this amount of
time.
0~64800 seconds
64800 seconds
20-01-09
03
CAR/SIE/Virtual Extension Delay Interval
CAR Keys/SIE Keys/Virtual Extensions set for
Delayed Ringing (refer to
15-11 : Virtual
Extension Delayed Ring Assignment
) ring the
extension after this interval.
0~64800 seconds
10 seconds
20-04-03
04
Intercom Interdigits Time (Intercom I/D
Timer)
When placing Intercom calls, extension users
must dial each digit in this time.
0~64800 seconds
10 seconds
21-01-02
05
Trunk Interdigits Time (Trunk I/D Timer)
The system waits for this time to expire before
placing the call in a talk state (Call Timer starts
after time expires, Voice Over and Barge-In are
not allowed until after time expires).
0~64800 seconds
5 seconds
21-01-03
06
Hotline Time Start Time (Hotline Start)
A Ringdown extension automatically calls the
programmed destination after this time.
0~64800 seconds
5 seconds
21-01-09