NEC SV8500 Operation And Maintenance Manual - page 100
– 53 –
CHAPTER 2
Operations of SV8500 Server
4. ROUTINE DIAGNOSIS
For confirming its own servicing status, the system automatically executes self diagnosis every day, and
displays the result of the diagnosis as a system message. By this function, possible causes for trouble can be
discovered in an early stage and possible trouble can be prevented from remaining undetected.
4.1
Related System Data
•
ASYD, SYS1, INDEX86,
b0 –
When routine diagnosis starts, and the result of the routine diagnosis is normal, the result
displays as System Message [
].
0/1: Not displayed/Displayed
b1 –
When the result of the routine diagnosis is abnormal, it displays as System Message [
0/1: Not displayed/To display
b3, b2 –
Processing at the time when Trunk Ineffective Hold is detected.
Note 1
Note 1:
Trunk Ineffective Hold is a continuous state other than idle state within a predetermined duration while
routine diagnosis is in progress. Whether it is detected/not detected, it is assigned by ASYD, SYS1, IN-
DEX 89.
Note 2:
When Trunk Ineffective Hold on the FCCS Network is detected, setting of ASYD, SYS1, INDEX 86,
b2·b3 and SYS1, INDEX 89, b4·b5 must be the same at all nodes on the network.
•
SYS1, INDEX 87, 88 - Routine Diagnosis Start Time
Start time should be such a time which the traffic of the office is the lowest.
To stop the routine diagnosis, set FF respectively to INDEX87, 88.
BIT
The trunks being held at present are forcibly
released, except the trunks being held on two-
way calls (station-to-station call, station-to-
trunk, external trunk-to-external trunk call).
All trunks being held at
the present are forcibly
released
LENS of the trunk detected
display as System Message
[
b3
b2
0
0
X
—
X
0
1
—
—
X
1
0
—
X
X
INDEX 87
0
2
(Hour)
2:00 a.m. is the start time.
INDEX 88
0
0
(Minute)