NEC SV8500 Operation And Maintenance Manual - page 659
– 612 –
CHAPTER 5
Operation Procedure for System with PIR
4. ATTCON/DESKCON FAULT
This section explains the fault repair procedure when a specific Attendant Console (ATTCON) is in any of the
following faulty conditions.
•
No speech can be made.
•
No operations can be made.
4.1 Check Point
When repairing an ATTCON/DESKCON fault, consider the following items:
(1) Check the cable connections on the backplane.
(2) When replacing the ATI circuit card for primary ATTCON/DESKCON, the system is placed under Night
Mode during replacement procedure.
(3) When replacing the primary ATTCON/DESKCON, the system is placed under Night Mode during
replacement procedure.
4.2 ATTCON/DESKCON Control
Each ATTCON/DESKCON is controlled from an ATI (PA-CS33) circuit card. ATI circuit card is controlled
from the CPU card via the INT on the TSW card. Figure 5-8 shows the control route of the ATI circuit card.
ATI (PA-CS33) circuit card is used as an interface card between the SV8500 Server and ATTCON/DESK-
CON. The card is mounted in slot 12.
DTI
RB
RA
TB
TA
Receive
Send
Loop-back
Cross Connection