NEC SV8500 Operation And Maintenance Manual - page 874
– 827 –
CHAPTER 7
Maintenance Commands
DSTN: Display of Station Data
1. Functional Outline
This command is used to display the registered Station Data corresponding to the designated Tenant and Station
Number. In addition, the information of Hot Line, Dterm Key Layout, Hunting, and Call Pickup, etc., can also
be displayed as the data related to the designated stations.
2. Parameters
Input Data
TN:
Tenant Number
STN:
Station Number [0-9, #, * (maximum six digits)]
Buttons
For display data selection
SHP:
Station Hunting Group-Pilot
KYD:
Key Data for Dterm
CPG:
Call Pickup Group
CPE:
Call Pickup Expand Group
PHN:
Phantom Station Number
SHC:
Station Hunting-Circular
SHU:
Station Hunting-UCD
HLS:
Hot Line Station
Note:
When the designated station has any of the above listed data, the corresponding button(s) can be
selected. If the data is necessary, click the button(s).
For execution order
Get:
View the display data.
Close:
Exit this command.
Output Data (by Parameters)
ETN: