NEC SV8500 Operation And Maintenance Manual - Mbrt: Make-Busy of Route
– 880 –
CHAPTER 7
Maintenance Commands
MBRT: Make-Busy of Route
1. Functional Outline
This command is used to assign IDLE/BUSY status for all the trunks in the route designated.
2. Parameters
Input data
RT:
Route Number of the external route/internal route. Table 7-1 provides the meaning of
the internal route number.
MB:
Make-Busy Information [0-1]
0=Make Idle
1=Make Busy
Table 7-1 Route Number Explanation
DATA
MEANING
DATA
MEANING
901
Attendant/Desk Console
902
Originating Register Trunk
903
Incoming Register Trunk
904
MF Receiver
905
Sender Trunk DP/PB
906
PB Receiver for Automated Attendant Service
907
AMP
908
Not used
909
Three-Way Conference Trunk
910-912
Not used
913
Three-Way Conference Trunk for ATTCON
914
Not used
915
Night Attendant Console
916
MFC Register
917
MFC Sender
918
Not used
919-926
Modem
927, 928
Not used
929
Data Signaling Trunk-Option
930
Rate Adapter Conversion Trunk
931-947
Not used