NEC SV8500 Operation And Maintenance Manual - 1-V:
– 232 –
CHAPTER 3
System Messages
1-V:
DLKC Data Transfer Failure (Temporary)
This message displays when a data sending error or no answer error occurs at the time of data transfer from CPU
to DLKC card.
System status of faulty DLKC card
Error Code
Details on Switching Network
Note:
This data displays when the STBY DLKC card is detected as faulty.
Default Alarm
Default Grade
Grade Modified
Lamp Modified
SUP
1
1:
XXXX
XX00
0000
0000
2:
0000
0000
0000
0000
3:
0000
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b0
b7
b6
b5
b4
b3
b2
b1
b0
b7
b1
b0
1 2
3
b0:
0/1 = System 0/System 1
1
01H: Firmware fault
02H: Data transfer time out to DLKC
03H: No answer time out (at DLKC)
04H: Data parity error
2
b0:
Status of Speech Path System (including DLKC)
0/1 = System 0 is ACT/System 1 is ACT
b1:
Status of basic clock
0/1 = System 0 is ACT/System 1 is ACT
b7:
Information on Reset of STBY DLKC
Note
0/1 = - /STBY DLKC card was reset
3