NEC SV8500 Operation And Maintenance Manual - page 242
– 195 –
CHAPTER 3
System Messages
CHAPTER 3
System Messages
1. Observation Method of System Message
System messages display during routine diagnosis, system operation status controlling, and fault
occurrence. Figure below shows an example of a system message.
System Message Example
(1) SYSTEM MESSAGE 3-E SUP LOCK UP FAILURE (TEMPORARY)
(2)
NEC TOKYO JUL 24 09:35
(3)
LP00-0-ACT
(4)
4:0000 0000 0000 0000 5:0000 0000 0000 0000 6:0000 0000 0000 0000
1:1102 0000 0000 0000 2:0000 0000 0000 0000 3:0000 0000 0000 0000
7:0000 0000 0000 0000 8:0000 0000 0000 0000 9:0000 0000 0000 0000
Meaning:
(1) : SYSTEM MESSAGE 3-E SUP LOCK-UP FAILURE (TEMPORARY)
Meaning of the message
Alarm Level
(Indicated by Alarm Lamp)
Note
System Message Number
(2) : Office Name, Date and Time
(3) : LP00-0-ACT
ACT/STBY indication for dual systems
Faulty processor/Related processor
System 0/1 indication for dual systems
(4) : Message detail data (notation by hexadecimal numbers)
Note:
There are four kinds of alarm information indicated by alarm lamps: MN, MJ,
SUP, and No Indication.