NEC SV8500 Operation And Maintenance Manual - page 508
– 461 –
CHAPTER 3
System Messages
09
01
01
PHF operation start
Not Applicable
02
Recovered from the network fault
03
Recovered by re-routing
02
01
Socket option error
Initialize PHF module
02
FCCS port fault
03
UDP packet sending error
04
Communication failure (major)
Peer-to-Peer FCCS network has
been disconnected because of fre-
quent packet loss. Contact the net-
work administrator and have the
cause investigated.
03
01
Restart sequence start
Not Applicable
02
Line fault
03
Continuous sending timed out
04
Continuous sending occurred
05
Alternate Routing
The office data has been assigned
wrongly, or network failure is
occurring. If system message ([33-
S] IP PKG Failure) has been output
as well, contact the network admin-
istrator. If only this message has
been output, check again the office
data
related to FCCS.
06
Communication failure (minor)
Packet loss is occurring. Check
whether the same system message
has been output at the opposite
node. If this message has been out-
put continuously, contact the net-
work administrator and have the
cause investigated.
07
PHF Communication Status Report
This message is for engineer only.
Definition of Fault Information
FNC
(
)
INF (
)
FLT (
)
Data of
-
Description
3
4
5
6 28