NEC SV8500 Operation And Maintenance Manual - page 514
– 467 –
CHAPTER 3
System Messages
The following provides detailed fault information and the solution by using the combination of data (INF, FLT, and
Detailed Info). These information are provided when FNC (
) indicates 04.
Table 3-3 Detailed Fault Information and The Troubleshooting
INF (
)
FLT (
)
Detailed Info
Description
Solution
05
03
20
0E
Failed to communicate between DPMs
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
Restart to communicate between DPMs
08
12
0C
Buffer Overflow
None
10
01
01
Detect NC (CPU) WDT
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
02
01
Detect PCMCONT-0 (DSP) WDT
03
01
Detect PCMCONT-1 (DSP) WDT
08
01
Detect VC0 (CPU) WDT
Reset IPELC (IPLC). If the fault
occurs again, replace the VC0 PKG
with a new one.
Recovery VC0 (CPU)
08
04
Failed to initialize VC0 (CPU) device
09
01
Detect VC1 (CPU) WDT (Sub PKG#1)
Reset IPELC (IPLC). If the fault
occurs again, replace the VC1 PKG
with a new one.
Recovery VC1 (CPU)
09
04
Failed to initialize VC1 (CPU) device
0A
01
Detect VC2 (CPU) WDT (Sub PKG#2)
Reset IPELC (IPLC). If the fault
occurs again, replace the VC2 PKG
with a new one.
Recovery VC2 (CPU)
0A
04
Failed to initialize VC2 (CPU) device
0B
01
Detect VC3 (CPU) WDT (Sub PKG#3)
Reset IPELC (IPLC). If the fault
occurs again, replace the VC3 PKG
with a new one.
Recovery VC3 (CPU)
0B
04
Failed to initialize VC3 (CPU) device
12
00
80
Failed to download programs
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
13
42
02
Memory Fault
Memory Fault Recovery
06
40
80
13
Failed to reserve OS resource
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
43
20
0E
Failed to communicate between DPMs
4A
80
16
Failed to set LAN related data
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
3
4
5
7
8