CHAPTER 5
Operation Procedure for System with PIR
Figure 5-35 Line Load Control Indication (DESKCON)
(3) Operations on PCPro
Line Load Control operates by entering the ALLC command from PCPro. Stations with RES=0 assigned
for ASFC SFI=16 (Line Load Control) will be restricted to originate a call. (Call termination is available).
Assign SYS1, INDEX59, bit0=1 of System Data to restrict the call termination from the trunk.
Note:
System Message [6-C] is not displayed until the restricted station goes off-hook. In this System Message,
the message is displayed toward LP which is applicable to the restricted station.
(4) Automatic Setting
If the usage rate of the CPU exceeds the system data usage rate, Line Load Control is automatically set. In
this case, System Message [6-C] displays. The station controlled and the contents of the Automatic Line
Load Control are the same as those in Step (1) Operations on the Attendant Console.
If the usage rate of the CPU drops below the system data usage rate, the Line Load Control is automatically
cancelled. In this case, System Message [6-D] displays.
COMMAND
COMMAND FULL NAME
Assignment of Line Load Control
1
4
7
*
2
5
8
0
3
6
9
#
Line Load indication
LLC is displayed on a Desk Console, when Line Load Control starts.
LLC
Desk Console
L1
L2
L3
L4
L5
L6