NEC SV8500 Operation And Maintenance Manual - page 428
of
975
– 381 –
CHAPTER 3
System Messages
Probable cause for the failure
b7
b3
b2
b1
b0
b0-b3: See the table below.
FLT ID
CCITT
ERROR
FACTOR
00
A
S (F = 1) frame is received.
01
B
DM (F = 1) response is received.
02
C
UA (F = 1) response is received.
03
D
UA (F = 0) response is received.
04
E
DM (F = 0) response is received.
05
F
SABME command is received.
06
G
N200 Timeout (Link is set)
07
H
N200 Timeout (Link is disconnected)
08
I
N200 Timeout (Link failure is restored
to normal)
09
J
N (R) frame error is received.
0A
K
FRMR frame is received (Link is re-
setup).
0B
L
Undefined frame is received.
0C
M
-
0D
N
Improper long frame is received.
0E
O
I-frame with I-field that exceeds N201
is received.
0F
-
-
10
-
Layer 1 down (for ILC)
40
-
FRMR frame is received. (Link is not
re-setup)
3