NEC SV8500 Operation And Maintenance Manual - 3-E:
– 237 –
CHAPTER 3
System Messages
3-E:
Lock-Up Failure (Temporary)
At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
system displays this data. When the failure is detected less than 15 times per hour, the failure is judged as
temporary.
Faulty Circuit Card Location
PM Restart Type
Default Alarm
Default Grade
Grade Modified
Lamp Modified
SUP
1
1:
XX00
0000
0000
0000
2:
0000
0000
0000
0000
3:
0000
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b6
b5
b4
b3
b2
b1
b0
b7
b0
1 2
b0-b4: Group
b5-b6: Unit (0-3)
b7:
Module Group
0/1 = Even-numbered MG/Odd-numbered MG
1
b0:
0/1 = B-monitor/Initial Restart
2