NEC SV8500 Operation And Maintenance Manual - page 796
– 749 –
CHAPTER 7
Maintenance Commands
CMWL: Control Message Waiting Lamp
1. Functional Outline
This command indicates ON/OFF status and controls the Message Waiting Lamp ON/OFF (MW Lamp) at the
station. If the station is a Dterm, this command can also control Message Waiting Display on the Dterm.
2. Parameters
Input Data
TYPE:
Type of Input (1,2)
1=Designation by Station Number
2=Designation by LEN
TN:
Tenant Number
STN:
A maximum of five digits for a Business system, and six digits for a Hotel system.
LENS:
Line Equipment Number
MCI:
Message Center MW Status (0,1)
0=OFF
1=ON
ATT:
Attendant Console MW Status (0,1)
0=OFF
1=ON
STA:
Station MW Status (0,1)
0=OFF
1=ON
VMM:
Voice Mail Module MW Status (0,1)
0=OFF
1=ON
Note 1:
This parameter appears when “1” is selected in TYPE.
Note 2:
This parameter appears when “2” is selected in TYPE.