Maintenance Commands
CBND: Calculate Bandwidth Data
1. Functional Outline
This command is used to calculate bandwidth data.
2. Parameters
Input data
START LOC-ID: Start location ID (0-4095)
END LOC-ID:
End location ID (0-4095)
Cycle:
Observation Cycle (10-300 seconds)
Start time:
Start time of observation (Year/Month/Day/Hour/Minute/Second)
DisplayRange:
Transit graph display time range of bandwidth.
Select the time (30 minutes, 1 hour, 2 hours, 4 hours, 6 hours, 12 hours, 24 hours).
Output Data
Start time:
Start time of observation
Last time of acquisition:Last time of observation
Current bandwidth data
A LOC-ID:Location ID A
B LOC-ID:Location ID B
Used bandwidth [Kbps]:Current used bandwidth value
Limit value [Kbps]:Current limit value of bandwidth
Average value [Kbps]:Average value of bandwidth in the observing period
Maximum value [Kbps]:Maximum value in the observing period
Maximum time:Time recorded maximum value (Year/Month/Day/Hour/Minute/Sec-
ond)
Restriction:Restriction counter
Buttons
Start:
Calculate bandwidth data.
Stop:
Stop the process.