– 522 –
CHAPTER 3
System Messages
When
= 03H (
Registry NG Factor
) is indicated
Note:
This is an example of the format for explanation. Actual start bit varies because it follows the undeter-
mined size of bits (
= 01H) explained in the previous page.
DTC
Block Number
Registry NG Factor
DRS Number
1:
XXXX
XXXX
XXXX
XXXX
2:
XXXX
XXXX
03XX
XX00
3:
XXXX
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b6
b5
b4
b3
b2
b1
b0
b7
b6
b5
b4
b3
b2
b1
b0
b7
b6
b5
b4
b3
b2
b1
b0
b7
b6
b5
b4
b3
b2
b1
b0
6
6
9 10
7
8
Data Length
7
A maximum of Eight Blocks.
Note
: Bits from
Reset Factor to
The number of blocks will be
output by the number of Block Number.
9
13
8
01H: Unregistered ID (System does not have any registration.)
02H: Not available. (Equipment that had tried to make a registration is
restricted.)
03H: Duplicated registry (Designated ID/Station Number has been already
registered. DtermIP is only available.)
05H: Invalid Accommodation Location. Function is available only when
Terminal (
Port Number of Terminal) is used.
07H: Failed to obtain PH (Equipment that had tried to make a registration
failed to obtain PH.)
09H: Equipment type is invalid. (Registration failed to obtain PH.)
0FH: A part of PH cannot be obtained.
10H: Exceeded Registration Capacity
11H: Resource is not available.
12H: Message Error
1
9
01H: First DRS
02H: Second DRS
03H: Third DRS
04H: Fourth DRS
10