NEC SV8500 Operation And Maintenance Manual - 3-H: Digital Line Warning
– 240 –
CHAPTER 3
System Messages
3-H: Digital Line Warning
This message displays when the DTI card detects an abnormal state of a digital line, but this failure has no
influence on the speech path. When the status worsens, the system issues [3-I] Digital Line Failure message.
Location of PM (LENS) with a fault
Kind of fault
Time Slot number of fault (This data
is valid only when the kind of fault
is 08H.)
Default Alarm
Default Grade
Grade Modified
Lamp Modified
SUP
2
1:
XXXX
XX00
0000
0000
2:
0000
0000
0000
0000
3:
0000
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b6
b5
b4
b3
b2
b1
b0
b7
b6
b5
b4
b3
b2
b1
b0
b7
b4
b3
b2
b1
b0
1 2
3
b0-b4: Group
b5, b6: Unit
b7:
0/1 = Even-numbered MG/Odd-numbered MG
1
01H = Frame alignment loss occurs three times a day
02H = Bit error rate is over 10
-6
03H = Slip occurs twice a day
04H = Multi-frame alignment loss occurs three times a day
08H = Fault-detection on the CCIS Bch
2
b0-b4: Time slot number in which the digital line failure occurred
(1-16, 17-31)
3