NEC SV8500 Operation And Maintenance Manual - page 747
– 700 –
CHAPTER 7
Maintenance Commands
ASSW: Assignment of Soft SW Data
1. Function Outline
This command changes and displays the settings of software switches on the CPU board.
Note:
The software switch data assigned by this command can be backed up by the MEM_HDD command. Us-
ing the MEM_HDD command, the backed up data can be verified.
Note:
If a software switch data is backed up on CF Card when the system is initialized, upload on the memory
when loading the office data in order to assign the software switch.
2. Parameters
System Select:
•
System 0
•
System 1
SYSTEM SELECT 0:
SW: 1-4
STS: ON/OFF
Note 1:
This parameter is for display only.
SYSTEM SELECT 1:
SW: 1-8
•
1: LAN Connector 3
•
2: LAN Connector 2
•
3: LAN Connector 1
•
4: LAN Connector 4
•
5-8: Not used
STS: ON/OFF
•
ON: Not detect fault
•
OFF: Detect fault
Note 2:
STS is not used and fixed to OFF when the SW is 5 to 8.
SYSTEM SELECT 2:
SW: 1-8 (Not used)
STS: OFF (Fixed)