NEC SV8500 Operation And Maintenance Manual - page 842
– 795 –
CHAPTER 7
Maintenance Commands
DICBD: Display of Individual Call Block Data
1. Functional Outline
This command is used to display the information of Individual Call Block Data.
2. Parameters
Input Data
TYPE:
Select the item to input data.
1: UGN/TELN
2: FPC/TN/STN
3: FPC/LENS
When “1: UGN/TELN” is selected in TYPE:
UGN:
Enter the User Group Number.
TELN:
Enter the Telephone Number (Maximum 16 digits).
When “2: FPC/TN/STN” is selected in TYPE:
FPC:
Enter the Fusion Point Code.
TN:
Enter the Tenant Number.
STN
Enter the Station Number.
When “3: FPC/LENS” is selected in TYPE:
FPC:
Enter the Fusion Point Code.
LENS:
Enter the Equipment Number.
Output Data
CB ACT:
Call Block List
0: Inactive
1: Active
AN BLK ACT:
Anonymous Call Block
0: Inactive
1: Active
BIN NO:
Bin Number [00-15]
DC:
Denial DC Number (Maximum 16 digits)
Buttons