NEC SV8500 Operation And Maintenance Manual - page 499
– 452 –
CHAPTER 3
System Messages
The following provides the fault information by using the combination of data (FNC, INF, and FLT).
Definition of Fault Information
FNC
(
)
INF (
)
FLT (
)
Data of
-
Description
01/02
01
01
None
Ether cable not connected
02
Failed to initialize Ether Controller
03
Failed to reset Ether Controller
04
Failed after 16 attempts to transmit,
due to collisions
05
Lost carrier during transmission
06
Collision has occurred after the slot
time of the channel has elapsed
07
CRC error on the incoming frame
08
Received Descriptor is not available
09
Received Buffer error
0A
Transmit Buffer error
0B
Exceeds allowed transmission limit
0C
FIFO overflow
02
01
Transmit Timer time out
02
Receives over-length message
03
Transmit Buffer overflow
03
01
-
: Destination IP Address
, :
Faulty Port No. (Origination)
,
: Faulty Port No. (Destination)
Time-to-live expired on packet
02
Bad header checksum in packet
03
Received bad format packet
04
Failed to frame received pack-
ets
05
Cannot fragment packet
3
4
5
6 28
6 9
10 11
12 13