NEC SV8500 Operation And Maintenance Manual - page 121
– 74 –
CHAPTER 2
Operations of SV8500 Server
•
Select “System Shutdown” in “Select Processing” list box.
•
Click “Execute” button to shut down the system.
•
Make sure that “PWR” lamp goes off on the CPU card.
Note:
Be sure to confirm “PWR” lamp is off on the CPU card before proceeding to the next step.
When PCPro Tools - System Shutdown is not available or does not work, press “PWR” switch on CPU
card for four seconds to shut down the CPU card
.
•
Press “PWR” switch for four seconds on the CPU card.
•
Make sure that “PWR” lamp is off on the CPU card.
Note:
Be sure to confirm “PWR” lamp goes off on the CPU card before proceeding to the next step.
STEP 6
Disconnect the LAN cables from the CPU card that is shut down.
Note:
It is recommended to put a mark on the cable not to reconnect a wrong cable.
STEP 7
Remove the front cover.
STEP 8
Remove the CF card from the CPU card.
STEP 9
Loosen the screws from the CPU card.
STEP 10 Pull the CPU card slowly toward you to remove from the system.
STEP 11 On the new CPU card, set the switches exactly same as those of the old CPU card.
STEP 12 Insert the removed CF card to the CF slot on the new CPU card.
STEP 13 Insert the new CPU card to the CPU slot.
•
Make sure that the connector is firmly inserted to the system.
Note:
Being inserted into the connector, the CPU card is automatically powered on.
STEP 14 Fasten the new CPU card with the screws.
STEP 15 Reconnect the LAN cables.
STEP 16 Make sure that the new CPU shows no abnormality by checking lamps on the front.
•
“PWR” lamp on the CPU card lights green.
•
“ON LINE” lamp on the CPU card will change as follows:
(1) OFF
o
(2)FAST flash
o
(3)SLOW flash
o
(4)steady ON
STEP 17 Set SW01 to the original key position.